DESCRIPTION:
Micron-rated cartridge filters
Depth or pleated cartridges for particulate removal and final protection of membranes, resins and sensitive equipment.
STANDARD SPECIFICATION:
– Lengths: 10–40 inch; configurations: DOE, 222/226 O‑ring
– Micron ratings: 0.2–100 µm (absolute/nominal)
– Materials: PP, PES, PVDF, glass fiber; FDA grades available
– Max pressure: 6–10 bar (housing dependent); Max temp: up to 80 °C
– Recommended terminal Δp: 1.5–2.0 bar
INDUSTRY USE CASES:
– Final protection for RO/NF/IX
– Guard filter after carbon beds or upstream of meters/nozzles
– Batch clarification and quality release filtration
PRETREATMENT / INTEGRATION NOTES:
– Select absolute ratings when protecting membranes
– Design for parallel banks to keep face velocity reasonable
– Plan spare sets; hygienic handling for sanitary services
STANDARD SCOPE OF SUPPLY:
– Cartridge sets, adapters and end‑caps
– Multi‑round stainless housings
– Differential pressure gauges/ transmitters
INLET REQUIREMENTS:
– Pretreated liquids; select absolute/nominal micron per duty
– Observe terminal Δp 1.5–2.0 bar
OPTIONS:
– Depth or pleated; DOE/222/226 ends
– Sanitary grades; sterilizable variants
HOMOLOGATIONS / STANDARDS:
– Housings per PED/ASME; cartridge certifications on request
PACKAGING / DELIVERY:
– Cartridge set with end-caps/adapters
– Packaging to avoid fiber shedding; lot traceability
PRICE DISPLAY:
Price on request